The performance characteristics of the digital pulse processor (DPP) as a low power pulse processor for gamma-ray semiconductor detector were analyzed. The FWHM energy resolution of the germanium detector was obtained as 0.35  and is in proper range of published value. The pulse resolution for peaking time of 0.8  obtained to be 1.16  respectively. A good range was obtained for the residual energy at various energy peaks. This lie between -2.3 KeV and 1.3KeV.The optimum peaking time was obtained at 6 μs where the FWHM goes through a minimum value from the plot of FWHM against peaking time. The dead time plot gave a linear fit for a peaking time of 3.2 μs and a curve at 19.2 μs.

References

  1. G. F. Knoll, Radiation Detection and Measurement, J.Wiley & Sons, York ,1989.
     Google Scholar
  2. ROOT Data Analysis Framework, https://root.cern.ch//.
     Google Scholar
  3. K. Debertin and R.G.Helmer, Gamma and X-Ray Spectroscopy with Semiconductor Detectors, North-Holland, Amsterdam, 1988.
     Google Scholar
  4. Laboratory Script, RDI 21, Digital DAQ and gamma-ray spectroscopy, University of Surrey, 2009.
     Google Scholar
  5. E. P.Inyang, E. P. Inyang and E.S.William,Assessment of the exposure of radio frequency radiation from Wi-Fi routers in Calabar metropolis Nigeria. The Nigerian Journal of Scientific Research. 2017; 16(2):490-494.
     Google Scholar
  6. E. P. Inyang, E. P.Inyang, E.S.William, P.O.Ushie, and G. A. Oteikwu, Measurement of Electric Field Radiation from 11KVA High Tension Power Line and its Environmental Effects in Calabar Metropolis, Nigeria. Physical Science International Journal. 2018; 18(2):2348-0130.
     Google Scholar
  7. S .Das, S. Samanta, R. Banick, R.Bhattacharjee,K. Basu, R.Raut,S.S.Ghugre,A.K.Sinha, S. Bhattacharva and S. Imran, A Compton suppressed detector multiplicity trigger based digital DAQ for gamma-ray spectroscopy. Nuclear Instruments and methods in Physics Reseach Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018; 893:138-145.
     Google Scholar
  8. R. Palit, S. Saha, J. Sethi, T. Trivedi,S.Sharma,B.S. Naidu, S. Jadhav, R.Donthi, P.B.Chavan,H.Tan, and W. Hennig. A high speed digital data acquisition system for the Indian National Gamma Array at Tata Institute of Fundamental Research. Nuclear Instruments and methods in Physics Reseach Section A: Accelerators,Spectrometers,Detectors and Associated Equipment, 2012; 680:90-96.
     Google Scholar
  9. R.C.Pereira, J. Sousa, A.M.Fernandes,F.Patricio, B. Carvalho, A. Neto, C.A.F. Varandas, G Gorini, M. Tardocchi,D.Gin and A. Shevelev. ATCA data acquisition system for gamma-ray spectrometry. Fusion engineering and design, 2008; 83:341-345.
     Google Scholar
  10. L. Di-Wen, W.Hong-Yi,L.Zhi-Huan, X. Chuan, and J. Lin. Perormance of digital data acquisition system in gamma-ray spectroscopy. Nuclear Science and Techniques, 2021; 32(8):1-11.
     Google Scholar
  11. M.A.Riley,J.Simpson, and E.S.Paul, High resolution gamma-ray spectroscopy and the fascinating angular momentum realm of the atomic nucleus. Physica scripta, 2016; 91:123002.
     Google Scholar
  12. E.P.Inyang, E.P.Inyang and M.B. Latif A Correlation: TL response of synthetic fused quartz with 60Co gamma (high dose) source and 90Sr/90Y Beta(low dose) source. Bulletin of Pure and applied Sciences-Physics, 2019; 38(1):06-12.
     Google Scholar
  13. R.S. Dong, L.Zhao, and J.J.Qin. Design of a 20-Gsps 12-bit time-interleaved analog-to-digital conversion system. Nuclear Science and Techniques, 2021; 32:18-25.
     Google Scholar